This document describes a test method of exposing specimens to artificial UV radiation in combination with a creep load. This method uses UV radiation source and ISO 899-1 for the tensile creep test. Fluorescent UV lamps specified in ISO 4892-3 or UVC lamp can be used as UV radiation sources. NOTE UVC exposure is described in IEC 60335-1.