This technical report provides the main thermo-physical parameters (thermal transmittance, heat capacity per unit area and periodic thermal transmittance) of the opaque envelope components most commonly used in existing buildings. These parameters can be used for energy assessments of existing buildings in the absence of more detailed information about the materials forming the structure.