(1) This document applies to the design of buildings and structural works, made of structural membrane
material. It provides guidance for the design of tensioned membrane structures, either mechanically or
pneumatically tensioned at a defined prestress level.
NOTE 1 Membrane materials comprise structural fabrics, coated structural fabrics and foils.
NOTE 2 For elements of tensile surface structures not governed by this Technical Specification (for example
made of steel, aluminium, wood or other structural materials), see relevant Eurocode parts.
(2) This document is concerned with the requirements for resistance, serviceability and durability of
tensioned membrane structures, as given in EN 1990.
NOTE 1 The safety criteria follow EN 1990 and will consider specific limit states for tensioned membrane
structures.
NOTE 2 Specific requirements concerning seismic design are not considered.
(3) Design and verification in this document is based on limit state design in conjunction with the partial
factor method.
NOTE Special attention goes to the action of prestress, snow, wind and rain action on membrane structures
and the combined effect of wind and rain or snow.
(4) This document covers analysis methodologies appropriate for tensioned membrane structures, from
analytical to full numerical simulation methods.
(5) This document considers connections between membrane materials and between membrane
materials and others.
(6) This document is applicable for hybrid membrane structures integrating different kinds of load
bearing behaviour (tension, compression, bending, inflation...), in a way that the structural membrane
shares loadbearing capacity with other structural elements made of different materials.
NOTE The term ‘hybrid structure' refers to this combined structural behaviour or use of materials.